MAD1001C-1-CH THERMO VAULT TEMPERATURE BOX THERMOVAULT DATA LOGGING KIT FOR OVEN/CONVEYOR- FROM USA

Oven temperature profiling on a regular basis can help ensure that a quality product is consistently produced. Profiling enables users to optimize their process, prove process control, and make corrections to a process when required.
The LogMaster oven temperature recorders are thermally insulated to withstand extreme temperatures. This, along with the stainless steel enclosure, allows the device to be used in applications such as powder coating cure ovens, wet coating cure ovens, batch ovens, and conveyor ovens. The external thermocouple probes provide accurate temperature measurements with fast response times.

The LogMaster user-friendly software easily downloads the data to a computer, where the readings may be displayed in degrees of Celsius, Fahrenheit, Kelvin, or Rankine. The software allows the user to view all data points, and even a summary of the data being viewed for calculations such as Mean Kinetic Temperature. If additional analysis of the data is needed, the data can be easily exported to MS Excel® by the simple click of a button.

The ThermoVault is a single channel oven temperature recorder. It has the ability to record up to 16,383 temperature measurements. The QuadThermoVault is a four channel oven temperature recorder with the ability to record up to 26,214 temperature measurements per channel. Both devices are easily removable from their insulated enclosures, which makes setup and data retrieval straightforward.

Internal Sensor Semiconductor, 0.1°C resolution, ±0.5°C accuracy
Remote Channel Thermocouple type J, K, T, E, R, S, B, or N
Resolution 0.1°C (J, K, T, E); 0.5°C (R, S, B)
Accuracy ±0.5°C (J, K, T, E); ±2.0°C (R, S, B)
Range J: –328 to 1832°F
K: –418 to 2501°F
T: –418 to 752°F
E: –418 to 1832°F
R and S: 32 to 3214°F
N: –418 to 2372°F
B: 392 to 3272°F
Channels ThermoVault: 1 Internal & 1 Remote
QuadThermoVault: 1 Internal & 4 Remote
OctThermoVault: 1 Internal & 8 Remote
Memory ThermoVault: 16,383/channel
QuadThermoVault: 500,000/channel
OctThermoVault: 500,000/channel
Sample Rate ThermoVault: One every 2 seconds up to one every 12 hours
QuadThermoVault: 4 readings per second up to 1 every 24 hours
OctThermoVault: 4 readings per second up to 1 every 24 hours
Battery ThermoVault: 3.6v lithium (LTC-7PN) 1 year typical
QuadThermoVault & OctThermoVault: 9v lithium (U9VL-J) 18 months typical
Dimensions ThermoVault: 4.8" x 4.8" x 2.5" (122mm x 122mm x 65mm)
QuadThermoVault: 9.1" x 5.9" x 2.45" (231mm x 149mm x 62mm)
OctThermoVault: 9.1" x 5.9" x 2.45" (231mm x 149mm x 62mm)
Environmental Range
Maximum Exposure Time
Ambient Temperature Single Channel Quad Channel Oct Channel
100°C (212°F) 52 min 110 min 110 min
150°C (302°F) 30 min 62 min 62 min
200°C (392°F) 22 min 45 min 45 min
250°C (482°F) 17 min 35 min 35 min
260°C (500°F) 16 min 33 min 33 min
300°C (572°F) 15 min 30 min 30 min
350°C (662°F) 12 min 25 min 25 min
0 to 95% RH non-condensing
Interface Pkg IFC110 or IFC200

*Optional Software code is MAD1001S

Location