Datalogger/Recorders
Sub Categories
Features: •Analysis for 3 phase multi-power system, 1P/2W, 1P/3W,3P/3W, 3P/4W •3 current probes ( CP-1201 ) are included, if change the current probes, the calibration procedures are not necessary •Current probe input signal/ranges with selection:Input signal (ACV):200 mV/300 mV/500 mV/1 V/2 V/3 VRanges (ACA) : 20 A/200 A/2000 A/30 A/300 A/ 3000 A. •Meter can cooperate the universal current probes •Measurement: V (phase-to-phase), V (phase-to-ground) A (phase-to-ground) KW / KVA / KVAR / PF (phase) KW / KVA / KVAR / PF (system) KWH / KVAH / KVARH / PFH (system) Phase angle •Harmonics display (1-50th order) •Simultaneous display of Harmonics and Wave form •Display of Waveform with Peak Values •Analysis of Total Harmonic Distortion ( THD ) •Graphic Phase diagram with 3-Phase system parameters •3 phase Voltage or Current Unbalanced Ratio ( VUR, AUR ) and Unbalanced Factor •Calculated Unbalanced Current through Neutral Line ( An ) Standard Accessories: * Instruction manual............... 1 PC * Test Leads (TL88-4AT).......... 1 Set (4 PCs) * Alligator clips (TL88-4AC) 1 Set (4 PCs) * Clamp Probe ( CP-1201 )....... 3 PCs * AC to DC 9V adapter..............1...
Features: •Analysis for 3 phase multi-power system, 1P/2W,1P/3W, 3P/3W, 3P/4W •Voltage & Current are the True RMS value. •True Power ( KW、MW、GW ) measurement. •Apparent Power ( KVA、MVA、GVA ) measurement. •Reactive Power ( KVAR MVAR、GVAR) measurement. •Watt-Hour ( WH、SH、QH、PFH ). •Power Factor( PF )、Phase Angle( Φ ). •Voltage measurement range : 10 to 600 ACV •Current measurement range: 0.2A to 1200 ACA. •Programmable CT ratio (1 to 600) and PT ratio (1 to 1000). •ACV input impedance is 10 Mega ohms. •Safety Standard : IEC 1010, CAT III 600V •Built-in clock and Calendar, real time data record with SD memory card , sampling time set from 2 to 7200 seconds. Just slot in the SD card into the computer, it can down load the all the measured value with the time information ( year/month/data/hour/mimute/second ) to the Excel directly, then user can make the further data analysis by themselves. •Measurement: * ACV * ACA * AC WATT ( True Power )AC WATT( Apparent Power )AC WATT( Reactive Power ) * Power factor * Phase angle * Frequency Standard Accessories: * Instruction manual.......................1 PC * Test Leads...
TEN810-Datalogging Large Wall Display Temperature /Humidity Monitor with 95dB Sound Alarm/Controller
Complete environmental monitor and alarm - Wall-Mounted LED type, easy reading - Alarm set for Hi and Low limit-Temperature and Humidity - Data Logging Capacity 30,000 records - LED displays real time data - USB interface- XL Display: 260 x 178 x 47mm- High Accuracy and high sensitivity
Dual display of temperature and humidity. - Select between different temperature scales (°C / °F). - Simultaneously hold both temperature and humidity readings. - Simultaneously hold both Maximum and Minimum and Average readings (MAX/MIN/AVG) with time marks. - Relative subtraction value (REL) function. - Alarm alert (SET) function. - Auto-power off. - DEW-POINT and WET-BULB temperature measurement. - Stores up to 200 readings Listing Details Application The Temperature /Humidity Meter has a highly accurate sensor chip to measure relative humidity and temperature. It is perfect for many industrial applications, laboratory and other types of work locations. Specification - Display: Dual LCD display. The maximum value on the primary display is 1999. The maximum value on secondary display is 9999. - Low Battery Indicator: When the LCD displayssymbol, please replace the battery. - Sampling Rate: 1 sample per second. - Power Supply: One 9V battery, NEDA...
IP66 water-proof, Data-Logger, USB RS-232, Max/ Min/ Avg, Dew point IP66 water-proof & dust-proof. Data-Logging up to 32000 readings USBhighspeeddownloading Max/Min/Avg/Hold Functions. Large LCD display with LED back-light. High accuracy and respond quickly USB and RS-232 output IP66,CE and RoHS approved
1392 EMF TESTER The EMF tester is designed to provide user a quick, reliable and easy way to measure electromagnetic field radiation levels around power lines, home appliances and industrial devices. The EMF tester is a cost effective, hand-held instrument designed and calibrated to measure electromagnetic field radiation at different bandwidths. Display micro Tesla & milli Gauss in the same tester. Data hold, Peak hold function - On-line computer (1391/1392) Data logging (1392) function. Display 3-1/2 digits. Max. indication 1999 Range 200 / 2000 milli Gauss 200 micro Tesla Resolution 0.1 / 1 milli Gauss 0.01 / 0.1 micro Tesla Number of Axis Single axis Band Width 30 Hz to 300 Hz Accuracy +/- (3% + 3d) at 50Hz / 60Hz Over-Input Display shows "OL" Sampling Time Approx. 0.4 second Battery 4 pcs size AAA (Alkaline Battery) Battery Life Approx. 60 hours Operating Temp and Humidity ...
*DESKTOP & WALL MOUNT TEMP./ HUMID. DATALOGGER *DATALOGGING into SD CARD, No software, No cables. SD card 1 GB to 16 GB Open with Microsoft Excel! Easy!RS232/USB PC COMPUTER interface
• Range - Humidity : 5 % to 95 % R.H. - Temperature : 0 ℃ to 50 ℃ - Range : -25.3 ℃ to 48.9 ℃ • Dimension : 177 x 68 x 45 mm • Weight : 489 g/1.08 LB. FEATURES : • Humidity/Temp., Dew point ( Humidity ), Wet bulb ( Humidity ), Type K/J thermometer, 4 kinds measurement are combined into one meter, intelligent and professional. • Type K, Type J thermocouple thermometer. • Fast humidity measuring response time. • Data hold, record max. and min. reading. • Microcomputer circuit, high accuracy. • RS232/USB PC COMPUTER interface.