FEATURES ● Indicates phase rotation.        ● Indicates phase presence.● No battery required.● Phase rotation phase presence indicated on large    liquid crystal display.● Small, rugged enclosure.● Color coded test leads.● Phase presence indication from as low as 40Vac to   as high as 500Vac.● Fused.● Lightweight, robust and compact.● EN 61010-1 CAT III 500V   EN 61010-2-032     SPECIFICATIONS       ELECTRICAL     Determination of the Phase Presence Nominal Voltage for Phase Presence Indication (the voltage required for the LCD L1, L2, L3 indicators to come on) From 40Vac to 500Vac. Frequency range From 15Hz to 400Hz. Determination of the Phases Rotary Field Direction:   Direction Indication by LCD Display(the voltage required to have the LCD Direction Arrows to indicates and the L1 L2 L3 or L3 L2 L1 indicators to show) From 40 to 500Vac. Frequency range From 15 Hz to 400Hz Protection     Over load 700V(between...

FEATURES ● Two functions in one unit: open phase and phase       sequence detection.● Neon light indicators.● Large size alligator clips for easy clipping onto switch-    boards terminals.● Allows you to check a wide range of 3-phase power     sources.● Special test leads length are available on request.     SPECIFICATIONS       Input voltage 100-500V AC Frequency range 45 - 70 Hz Circuit structure All electronic (not mechanical) AC power consumption Approx. 7mA Dimensions 102(L) × 78(W) × 32.5(D)mm Weight Approx. 228g Safety standard EN 61010-1 CAT III 500V EN 61326-1

FEATURES ● Two functions in one unit: open phase and phase      sequence detection.● Neon light indicators.● Large size alligator clips for easy clipping onto switch-   boards terminals.● Checks a wide range of 3-phase power sources.● Ideal for installing conveyor lines, pump systems and    interconnected drivers.● Water proof.● Special test leads length are available on request.     SPECIFICATIONS       Input voltage 100-500V AC Frequency range 45 - 70 Hz Circuit structure All electronic (not mechanical) AC power consumption Approx. 7mA Dimensions 102(L) × 78(W) × 32.5(D)mm Weight 862 PR : 115g Test leads : 97g Total : Approx. 212g Safety standard EN 61010-1 CAT III 500V / CAT IV 300V EN 61326-1

FEATURES ● The 865 PR is a detector with LEDs to show the de-    tection better visible than neon.         ● Three functions in one unit, including open phase,     phase sequence and 3 phase motor rotation.● Designed for checking a wider range of 3 phase         power source from 100V to 500V.● Indicates R.S.T LEDs which frequency range from 40Hz to 400Hz.● Wide range detection of motor frequency range from 2Hz to 400Hz.● Fixed magnets for convenient measurement.     SPECIFICATIONS       Measurement principle Contact Live Wire Input voltage 100-500Vac Frequency range 40Hz-400Hz Operating temperature & humidity 0°C ~ 40°C Max. 80% R.H. Storage temperature & humidity -10°C ~ 50°C Max. 80% R.H. Cable length Approx. 1m Dimensions 128(L) x 72(W) x 44(D)mm Weight (battery included) Approx. 220g  Power source 9V (6F22) × 1 Safety standard EN 61010-1 CAT III 500V EN 61326-1 EN 61557-1 ...

FEATURES ● Three functions in one unit: open phase, phase     sequence and motor rotation indication.    ● Large size alligator clips for easy clipping onto switch-   boards terminals.        ● Highly reliable.     ● Identifies 3 phase sequence and open phase check.● Ideal for installing conveyor lines, pump systems and     interconnected drivers.     SPECIFICATIONS             Input voltage 100-500V AC Frequency range 45-70 Hz Circuit structure All electronic (not mechanical) Power requirement 9V (6F22) × 1 Power consumption Consumption current approx. 14mA of motor rotation field tester AC power consumption Approx. 7mA Dimensions 153(L) × 72(W) × 35(D)mm Weight (battery included) Approx. 200g Safety standard EN 61010-1 CAT III 500V EN 61326-1

FEATURES ● Two functions in one unit: open phase and phase sequence detection.● Lamps let you determine at-a-glance if phase is open.● Large size alligator clips for easy clipping onto switch-boards terminals.● Checks a wide range of 3-phase power sources.● Special test leads length are available on request.● Push button switch is designed to minimize damage due to negligence.     SPECIFICATIONS       Voltage 200V-600V AC Frequency response 50 / 60 Hz Operating temperature & humidity 0°C ~ 40°C at 80% Max. relative humidity Storage temperature & humidity -10°C ~ 50°C at 90% Max. relative humidity Cord 1.1m each of red(R), white(S) and black(T) cord Dimensions 134(L) × 85(W) × 45(D)mm Weight Approx. 530g Safety standard EN 61010-1 CAT Ⅳ 600V EN 61010-2-31

FEATURES ● Two functions in one unit: open phase and phase sequence detection.● Lamps let you determine at-a-glance if phase is open.● Large size alligator clips for easy clipping onto switch-boards terminals.● Checks a wide range of 3-phase power sources.● Special test leads length are available on request.● Push button switch is designed to minimize damage due to negligence.     SPECIFICATIONS       Voltage 200V-600V AC Frequency response 50 / 60 Hz Operating temperature & humidity 0°C ~ 40°C at 80% Max. relative humidity Storage temperature & humidity -10°C ~ 50°C at 90% Max. relative humidity Cord 1.1m each of red(R), white(S) and black(T) cord Dimensions 134(L) × 85(W) × 45(D)mm Weight Approx. 530g Safety standard EN 61010-1 CAT Ⅳ 600V EN 61010-2-31

FEATURES ● Two functions in one unit: open phase and phase sequence detection.● Lamps let you determine at-a-glance if phase is open.● Large size alligator clips for easy clipping onto switch-boards terminals.● Checks a wide range of 3-phase power sources.● Special test leads length are available on request.● Push button switch is designed to minimize damage due to negligence.     SPECIFICATIONS       Voltage 200V-600V AC Frequency response 50 / 60 Hz Operating temperature & humidity 0°C ~ 40°C at 80% Max. relative humidity Storage temperature & humidity -10°C ~ 50°C at 90% Max. relative humidity Cord 1.1m each of red(R), white(S) and black(T) cord Dimensions 134(L) × 85(W) × 45(D)mm Weight Approx. 530g Safety standard EN 61010-1 CAT Ⅳ 600V EN 61010-2-31