Fluke 115 TRMS Digital Multimeter

The Fluke 115 is for general purpose electrical and electronic test requirements, the Fluke 115 true-rms digital multimeter provides the perfect answer. Its simple operation, compact design and ease of use makes it perfect for quick verifications and field service use.

The Fluke 115 displays true-rms voltage and current readings with 6000 count resolution, tests diodes, frequency, continuity and capacitance and provides Min/Max/Average readings to record signal fluctuations. A large white LED backlight aids work in poorly lit areas. Its easy-open battery access door makes battery changes a snap.

Fluke 115 multimeters are independently tested for safe use in CAT III 600V environments.

 
Specifications
Accuracy specifications
Function Range Resolution Accuracy ±
([% of Reading] + [Counts])
DC Millivolts 600.0 mV 0.1 mV 0.5 % + 2
DC Volts 6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
0.5 % + 2
AC millivolts
true-rms
600.0 mV 0.1 mV 45 Hz to 500 Hz: 1.0% + 3
500 Hz to 1 kHz: 2.0% + 3
AC volts
true-rms
6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
45 Hz to 500 Hz: 1.0% + 3
500 Hz to 1 kHz: 2.0% + 3
Continuity 600 Ω 1 Ω Beeper on < 20 W, off > 250 W;
detects opens or shorts of 500 µs or longer
Ohms 600.0 Ω
6.000 kΩ
60.00 kΩ
600.0 kΩ
6.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.9% + 2
0.9% + 1
0.9% + 1
0.9% + 1
0.9% + 1
1.5% + 2
Diode test 2.000 V 0.001 V 0.9 % + 2
Capacitance 1000 nF
10.00 µF
100.0 µF
9999 µF
1 nF
0.01 µF
0.1 µF
1 µF
1.9 % + 2
1.9 % + 2
1.9 % + 2
100 µF to 1000 µF: 1.9 % + 2
> 1000 µF: 5 % + 20
LoZ capacitance (power-up option) 1 nF to 500 µF 10 % + 2 typical
AC amps true-rms
(45 Hz to 500 Hz)
6.000 A
10.00 A
20 A overload for 30 seconds maximum
0.001 A
0.01 A
1.5% + 3
DC amps 6.000 A
10.00 A
20 A overload for 30 seconds maximum
0.001 A
0.01 A
1.0% + 3
Hz (V or A input) 99.99 Hz
999.9 Hz
9.999 kHz
50.00 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1% + 2
Frequency counter sensitivity
Input range Typical sensitivity (rms sine wave)
5 Hz to 45 Hz 45 Hz to 5 kHz 5 kHz to 10 kHz 10 kHz to 50 kHz
Volts AC 6 V
60 V
600 V
0.2 V
2 V
20 V
0.2V to 0.3V
2V to 3V
0V to 30V
0.3 V to 0.4 V
3 V to 4 V
30 V to 40 V
0.4 V to 1.0 V
4 V to 10 V
40 V to 100 V
AC Amps 6 A
10 A
N/A 0.4 A
0.5 A
N/A N/A
Input characteristics
Function Input impedance 
(nominal)
Common mode rejection ratio
(1 kW unbalanced)
Normal mode rejection
Volt AC > 5 MΩ < 100 pF >60dB at dc, 50 or 60Hz -
Volts DC > 10 MΩ < 100 pF >100dB at dc, 50 or 60Hz > 60 dB at 50 or 60Hz
Auto-V LoZ ~3 kΩ < 500 pF > 60dB at dc, 50 or 60Hz -
Ohms Open circuit test voltage Full scale voltage Short circuit current
To 6.0 MΩ To 6.0 MΩ
< 2.7 V dc < 0.7 V dc < 0.9 V dc < 350 µA
Diode Test < 2.7 V dc 2.000 V dc < 1.2 mA
General specifications
Function Description
Maximum voltage
between any
terminal and earth ground
600 V
Surge protection 6 kV peak per IEC 61010-1 600V CAT III, Pollution Degree 2
W Fuse for A input 11 A, 1000 V FAST 17 kA Fuse (Fluke PN 803293)
Display Digital: 6,000 counts, updates 4/sec; Bar Graph: 33 segments, updates 32/sec
Temperature Operating: -10°C to +50°C; Storage: -40°C to +60°C
Humidity 0% to 90% to 35°C
75% to 40°C
45% to 50°C
Temperature coefficient 0.1 x (specified accuracy/°C) (< 18°C or > 28°C)
Operating altitude 2,000 meters
Battery 9 Volt Alkaline, NEDA 1604A/IEC 6LR61
Battery life Alkaline: 400 hours typical, without backlight
Safety compliances ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA C22.2 No 61010-1-04, UL 6101B (2003) and IEC/EN 61010-1 2nd Edition for measurement Category III, 600 V, Pollution Degree 2, EMC EN61326-1
Certifications UL, CSA, TUV, N10140 , VDE
IP rating
(dust & water protection)
IP42

Location

Ask about this product