Kyoritsu

  • Filter

Continuity and Insulation Testing • Live circuit warning LED:Immediate illumination of a warning lamp if the circuit under test is live • Auto Discharge:Allows fast and safe discharge of electrical energy stored in capacitive circuits following testing • Integral overload protection on internal continuity and insulation test circuitry • Autoranging • 500V DC test voltage for insulation tests • 200mA short circuit current on continuity ranges

Complies with IEC 61557 • Designed to IP 54 Rating • Live circuit and wiring connection check LED's • Triple ranges insulation tests at 250, 500 and 1000V • Triple range loop and PSC tests 15mA test current at 200Ω/2000Ω range(No RCD Trip) • Phase angle selection on RCD ranges • Polarity switch for continuity tests • Auto-null facility for continuity tests • Earth probe for loop impedance testing on extraneous metalwork • Contact Voltage Reading • Test of a large kind of RCD's: Standard, Selective, AC and A(DC sensitive breakers)

Designed to meet IEC 61010-1 CAT.III 600V • Test leads with remote control switch.(For insulation&Simplified Earth Test) • Back light function. • Color coded scales and range switch position for easy reading. • Automatic warning when resistance of auxiliary earth spikes is in excess of tolerance. • Can be hung around the neck for both hand’s operation.

Anti-Trip Technology for complete trip free Loop testing on all RCDs rated 30mA and above. • Dual Display allows simultaneous measurements like Loop & PFC/PSC. • Two wire connection for Loop L-L, L-N and PSC testing is possible. • Phase rotation, Voltage and Frequency measurements. • Lock-down test button for 'hands free' testing with auto-start operation.

Custom microprocessor controlled for highest accuracy and reliability. • 3 LEDs for checking correct wiring status. • 15mA LOOP measurement:LOOP impedance 2000Ω range measurement is carried out with low test current (15mA).The current will not cause tripping out involved RCD even the one with the lowest nominal differential current (30mA). • Direct reading of Prospective Short Circuit Current (PSC). • Safe voltage measurement function. • Large custom digital display readout on all models. • Measure low loop resistances(resolution of 0.01Ω) • Automatic lock-out if test resister overheats. • Large custom digital display readout . • Visual indication of reversed phase and neutral wiring at socket. • Designed to IP54 Rating • Complies with IEC 61557

Category: Logger

3 channel inputs for the simultaneous recording of Leakage Current, Load Current and Voltage • Power Quality analysis(only on KEW 5020)(Power Quality:Reference voltage, Swell, Dip, Short power Interruptions)   Large Capacity for storing 60,000 data points 60,000 data points can be recorded when 1ch is used, and when all the three channels are used, 20,000 data points per channel can be recorded   Lowpass Filter will filter out the harmonics(Cutoff Frequency = Approx. 160Hz)   LED flickers when the preset current / voltage value is exceeded   CALL: Confirmation of recorded data • The following can be displayed: number of recorded data points, (max+ min+ peak) value for each channel complete with time/date information in the Normal recording mode. (Detected values (i.e. when values are outside preset limits ) can be displayed in other recording modes) • RECALL: The last 10 recorded data points including time/date can be recalled on the logger display

Category: Logger

THE LEAKAGE CURRENT IS RECORDED BY 3CH INPUT60,000 DATA IS RECORDED 60,000 data is recorded when 1ch is used and when three all channels are used, 20,000 data is recorded for each channel Continuous measurement time   About 40 days   Data where it doesn’t disappear even if battery is consumed   Data doesn’t disappear by using the nonvolatile memory when the battery is consumed and the battery is exchanged. (warranty for 10 years)   Battery residual display   The battery state is displayed by 4 stages. (When blinking is displayed, it is possible to measure for about one day)   The present time, recording intervals, the start of recording, the recording method, the name of monitoring site and the comment can be set by using supplied software

Applicable model 5010/5020 Conductor size Φ24 Rated current AC 100A Output voltage AC 500mV/100A (AC 5mV/A) Accuracy |±2.0%rdg±0.3mV (50/60Hz)|±3.0%rdg±0.5mV (40Hz~1kHz) Withstand voltage AC 3540V for 5 seconds Cable length Approx. 2m Output connector MINI DIN 6pin Operating temperature ranges 0~40ºC, less than 85% RH (without condensation) Output impedance Approx. 9.5Ω Applicable standards IEC 61010-1:2001,IEC 61010-2-032:2002,CAT.III 300V pollution degree 2 Dimensions 97(L) x 59(W) x 26(D) mm Weight Approx.150g Accessories 9095 (Portable case), Instruction manual, Cable marker Option 7146 (Banana Φ4 adjuster plug)7185 (Extension Cable)